Emulex: Way to reset the correct HBA after Changes with IBM Tapes were made in the SAN
Create a list of all manageable hbas:
server:/ # hbacmd listhbas Manageable HBA List Port WWN : 10:00:00:00:c9:97:78:e8 Node WWN : 20:00:00:00:c9:97:78:e8 Fabric Name : 10:00:00:05:1e:a6:74:ce Flags : 8000fe0d Host Name : server Mfg : Emulex Corporation Serial No. : BT95071947 Port Number : 0 Mode : Initiator PCI Bus Number : 2 PCI Function : 0 Port Type : FC Model : LPe11002
Which devices are connected to the HBA:
server:/ # hbacmd targetmapping 10:00:00:00:c9:97:78:e8
Reset the hba:
server:/ # hbacmd reset 10:00:00:00:c9:97:78:e8
Rescan
systool -c fc_host -v host3 echo "- - -" > /sys/class/scsi_host/host0/scan